Model | KGS-3 | KGS-4 | KGS-5-380 | KGS-6.5 | KGS-7 | KGS-10 | KGS-12 | KGS-15 | KGS-20 | KGS-25 | KGS-30 | |
Daya Input (KW) | 2.8 | 3.2 | 4.5 | 5.5 | 6.3 | 9.2 | 11 | 13 | 18 | 22 | 26 | |
Daya panas (KW) | 11.5 | 13 | 18.5 | 33.5 | 26 | 38 | 45 | 53 | 75 | 89 | 104 | |
Power Supply | 220/380V | 380V/3N/50HZ | ||||||||||
Suhu banyu sing dirating | 55°C | |||||||||||
Suhu Banyu Max | 60°C | |||||||||||
Cairan sirkulasi M3/H | 2-2.5 | 2.5-3 | 3-4 | 4-5 | 4-5 | 7-8 | 8-10 | 9-12 | 14-16 | 18-22 | 22-26 | |
Jumlah kompresor (SET) | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 4 | 4 | 4 | |
Ext.Ukuran (MM) | L | 695 | 695 | 706 | 706 | 706 | 1450 | 1450 | 1500 | 1700 | 2000 | 2000 |
W | 655 | 655 | 786 | 786 | 786 | 705 | 705 | 900 | 1100 | 1100 | 1100 | |
H | 800 | 800 | 1000 | 1000 | 1000 | 1065 | 1065 | 1540 | 1670 | 1870 | 1870 | |
NW (KG) | 80 | 85 | 120 | 130 | 135 | 250 | 250 | 310 | 430 | 530 | 580 | |
Refrigerant | R22 | |||||||||||
Sambungan | DN25 | DN40 | DN50 | DN50 | DN65 |
Hotel minangka papan sing nguntungake, mula kita kudu nyuda biaya operasi lan biaya pangopènan.Air energi pompa panas sistem banyu panas iku pilihan becik kanggohotelsistem pemanas banyuem.
Pompa panas sistem banyu panas generasi anyar saka pangayoman lingkungan teknologi dhuwur lan peralatan nyimpen energi, Dibandhingake karo boiler batu bara, boiler lenga murub, ketel listrik, pump panas bisa ngirit energi minangka dhuwur minangka 75% utawa luwih, lan pump kupluk duwe kaluwihan kaya nggunakake stabil, tingkat Gagal kurang lan urip dawa.Apa maneh, ora bakal kena pengaruh cuaca lan musim.
Unit utama pompa panas sumber udara:2.5-50HP utawa daya luwih gedhe miturut syarat nyata.
Tank panyimpenan banyu panas:0.8-30M3 utawa kapasitas luwih gedhe miturut syarat nyata.
Pompa sirkulasi
Katup ngisi banyu adhem
Kabeh fittings perlu, klep lan pipe line
Pompa booster banyu panas(Kanggo nambah tekanan pasokan banyu panas menyang padusan njero ruangan lan keran...)
Sistem kontrol banyu bali(Kanggo njaga suhu banyu panas tartamtu saka pipa banyu panas lan priksa manawa pasokan banyu panas njero ruangan cepet)
Konfigurasi (model beda) item 6-7 miturut kahanan nyata (kayata jumlah padusan, jubin bangunan, lsp)
Kepiye cara milih pompa panas sing tepat lan ngrancang sistem pompa panas udhara kanggo banyu kanggo proyek hotel sampeyan?Sampeyan kudu nimbang faktor ing ngisor iki:
1. Ora ana puncak banyu panas ing hotel, amarga hotel nduweni tamu 24 jam saben dina, kita kudu mesthekake yen ana pasokan banyu panas 24 jam sedina muput;
2. Miturut peraturan sing relevan, hotel bintang nduweni syarat sing luwih dhuwur babagan kualitas banyu panas, kayata banyu panas bisa diprodhuksi sanalika tunyuk diuripake, lan sumber banyu ora bisa mandheg ing mangsa;
3. Konsumsi banyu luwih dhuwur.Proyek banyu panas biasa umume dirancang miturut 50L / wong, dene volume banyu sing dirancang kanggo kamar standar ing hotel kira-kira 200L, kanggo kamar karo bathtub yaiku 140-300l, kanggo suite senior yaiku 300L-400L;
Sampeyan bisahubungi kitakanggo saran desain sistem kanggo hotel sampeyan.