Jinis | Low Ambient Suhu Sumber Udara Pompa Panas | Material omah | Plastik, lembaran galvanis |
Panyimpenan / Tankless | Pemanasan Sirkulasi | Instalasi | Freestanding, Wall Mounted / Freestanding |
Gunakake | Banyu Panas / Pemanasan Lantai / Pemanasan Fancoil lan Pendinginan | Kapasitas Pemanasan | 4,5-20KW |
Refrigerant | R410a / R417a / R407c / R22 / R134a | Kompresor | Copeland, Copeland Scroll Compressor |
Tegangan | 220V 〜lnverter, 3800VAC/50Hz | Power Supply | 50/60Hz |
Fungsi | Pemanasan omah, Pemanasan Ruang & Banyu Panas, Pemanasan Banyu Kolam, pendinginan lan DHW | Pulisi | 4.10-4.13 |
Penukar panas | Shell Heat Exchanger | Evaporator | Sirip Aluminium Hidrofilik Emas |
Suhu Sekitar Kerja | Minus -25C-45C | Tipe Kompresor | Kompresor Scroll Copeland Kab |
warna | Putih, Grey | Aplikasi | Jacuzzi Spa / Kolam Renang, Hotel, Komersial lan Industri |
Daya Input | 2,8-30KW | Cahya Dhuwur | pompa panas suhu kadhemen, pompa panas sumber udara inverter |
Apa prinsip kerja pompa panas sumber udara suhu sekitar rendah?
Unit pompa panas minangka sistem tertutup sing kasusun saka evaporator, kondensor, kompresor lan katup ekspansi, sing diisi karo jumlah refrigeran sing cocog.
Prinsip operasi pompa panas adhedhasar prinsip siklus Carnot mbalikke: refrigeran cair pisanan nyerep panas ing udhara ing evaporator lan nguap kanggo mbentuk uap (vaporization), lan panas laten penguapan yaiku panas sing dibalekake.Banjur dikompres menyang suhu dhuwur lan gas tekanan dhuwur dening kompresor lan mlebu kondensor kanggo kondensasi dadi cairan (liquefaction) kanggo ngirim panas sing diserap menyang banyu blumbang sing dibutuhake, refrigeran cair bali menyang tutup ekspansi sawise depressurization lan expansion liwat tutup expansion, nyerep panas lan nguap kanggo ngrampungake siklus.Kanthi cara iki, terus-terusan nyerep panas saka sumber suhu rendah lan ngasilake banyu kolam renang sing digawe panas kanggo langsung tekan suhu sing wis ditemtokake.
Model | KDR-03 | KDR-05S | KDR-05-G | KDR-07-G | KDR-10-G | KDR-15 | KDR-20 | KDR-25 | |
HP | 3 hp | 5 hp | 5 hp | 7 hp | 10 HP | 15 HP | 20 HP | 25 HP | |
sumber daya | 220V/380V | 220V | 380V | 380V | 380V | 380V | 380V | 380V | |
daya input | 2.8 | 4.2 | 4.7 | 5.2 | 9.2 | 13 | 18.5 | 20.5 | |
Output daya panas ing suhu lingkungan sing beda. | (20℃) | 10.8 | 16.2 | 18 | 20 | 35.4 | 50 | 71.2 | 78.9 |
(6/7℃) | 9 | 13.7 | 15.3 | 16.9 | 30 | 42.3 | 60 | 66.6 | |
(-6/7℃) | 6.9 | 10.3 | 11.5 | 12.7 | 22.5 | 319 | 453 | 50.2 | |
(-15℃) | 5.9 | 8.8 | 9.9 | 10.9 | 19.3 | 273 | 38.9 | 43 | |
(-20℃) | 5.2 | 7.8 | 8.7 | 9.6 | 17 | 24 | 34.2 | 37.9 | |
Output daya cooling | 8.0 | 12.0 | 13.4 | 14.8 | 26.2 | 37.1 | 52.7 | 68.4 | |
Arah stopkontak kipas | Sisih | Sisih | Sisih | Sisih | Sisih | Sisih | Ndhuwur | Ndhuwur | |
V\faler sambungan | DN25 | ON25 | DN25 | DN25 | DN32 | DN40 | DN50 | DN50 | |
Laju Cairan (M3/H) | 2-3 | 4-5 | 5-6 | 5-7 | 7-10 | 12-15 | 15-20 | 20-25 | |
Dimensi - s | (MM) | 1152 | 1190 | 1190 | 1190 | 1350 | 1350 | 1800 | 1800 |
(MM) | 422 | 425 | 425 | 425 | 645 | 645 | 1100 | 1100 | |
(MM) | 768 | 1240 | 1240 | 1240 | 1845 | 184S | 2100 | 2100 | |
BOOT (kg) | 130 | 180 | 160 | 220 | 310 | 355 | 630 | 780 |
Dibandhingake karo Pumps panas biasa, ing - 10 ℃ lan Suhu ngisor, suhu penguapan kurang banget, asil ing penguapan kurang, asil ing volume udara bali kurang saka kompresor, kang mengaruhi kondensasi lan release panas.Cabang sing nambah entalpi injeksi sing nyambungake kompresor ditambahake menyang pompa panas suhu sekitar ultra rendah.Nalika udhara bali saka kompresor ora cukup, cabang nambah enthalpy injeksi bakal nggawe hawa kanggo kompresor, supaya release panas saka condenser bakal tambah, supaya isih bisa gawé panas biasane ing suhu banget kurang.